Setting up a Virtual / Simulated Optical Network using the Mininet-Optical Software Emulator

This wiki page contains a tutorial for setting up an optical network using Mininet-Optical.

This is a Mininet-Optical version of the tutorial at Tutorials/Optical/Tutorial1. It is intended to show how an experiment designed for the COSMOS testbed may be adapted for use in a software emulation environment, and how Mininet-Optical may be used to design experiments that will later be run on the COSMOS hardware testbed.

Please refer to Tutorials/Optical/Tutorial1 to compare the hardware and software testbed environments.

Converted by: Bob Lantz

Original (hardware) tutorial Authors:

Artur Minakhmetov, Telecom Paris : artur.minakhmetov[at]telecom-paris.fr
Craig Gutterman, Columbia University : clg2168[at]columbia.edu
Michael Sherman, Rutgers University : msherman[at]winlab.rutgers.edu
Jiakai Yu, University of Arizona : jiakaiyu[at]email.arizona.edu
Tingjun Chen, Columbia University: tc2668[at]columbia.edu

Change Log

26 July 2022: created new version for Mininet-Optical.


Description

The COSMOS testbed enables creation and use of optical networks of various topologies. An example of how an optical network could be configured and used is provided. A simple experiment on switching of optical paths is described.


Compute Nodes and ToR switch interfaces used

  • Each compute node has 1 Ethernet interface:
    server1-eth0
    server2-eth0
    server2-eth0
    
  • There are three ToR Ethernet interfaces:
    tor1-eth111
    tor2-eth112
    tor3-eth113
    
  • and three WDM transceivers, with separate output and input ports:
tor1-wdm320/321
tor2-wdm290/291
tor3-wdm310/311

Experiment_1 Context

Fig.1 Logical Topology of Experiment_1

The experiment consists of changing the light path from ToR1←→ToR2 to ToR1←→ToR3, representing changing of the light path in a C-RAN when “Client” wants to move its base-band processing from “Edge Cloud” to “Central Cloud”.

Experiment includes 3 servers:

server1
server2
server3

Experiment includes 4 ROADMs:

roadm1 (localhost:1831)
roadm2 (localhost:1832)
roadm3 (localhost:1833)
roadm4 (localhost:1844)

3 ToR interfaces are connected to the 3 servers:

tor1-eth111 <--> server1
tor2-eth112 <--> server2
tor3-eth113 <--> server3

3 Ethernet interfaces and 3 WDM transceivers will be connected within the ToR switch:

tor1-eth111 ; tor1-wdm320/321  (output/input)
tor2-eth112 ; tor2-wdm290/291  (output/input)
tor3-eth113 ; tor3-wdm310/311  (output/input)

We are assigning next wavelengths to the transceivers:

1553,30 nm 193,00 with bandwidth ~[192.95;193.05] Thz
This corresponds to channel 34 in Mininet-Optical's default channel grid.

Prerequisites: Installing Mininet-Optical

Before starting this tutorial, you will need to have Mininet-Optical installed. If it isn't installed already, you can follow the Installation and Walkthrough instructions at https://mininet-optical.org.

The tutorial topology and a sample configuration script should be found in ~/mininet-optical/examples/cosmostutorial.py and ~/mininet-optical/examples/config-cosmostutorial.sh. If they are not there, you may need to fetch and check out the appropriate branch from github and install it using make install.


Setting Up the Optical Topology

In the COSMOS optical testbed, all devices are connected to a Calient S320 space switch. This switch serves as a programmable patch panel that allows any port to be connected to any other port, enabling realization of arbitrary topologies with fast reconnection between experiments.

It is possible to create a virtual space switch/programmable patch panel in Mininet-Optical to emulate the COSMOS optical testbed itself, but for this tutorial we will implement the topology using Mininet-Optical's topology API.

The Mininet-Optical emulated network is created using a Python script, examples/cosmostutorial.py. Take a look at it now to see how the topology is implemented.

The topology itself is created using Mininet's high-level topology template API. Specifically, we create a subclass of class Topo and override the build() method:

class TutorialTopo( Topo ):
...
    def build( self ):

ROADMs and ToR switches are added using addSwitch() calls:

        # ROADMs
        NC = NetconfPortBase
        roadm4 = self.addSwitch('roadm4', cls=LROADM, netconfPort=NC+4)
        ...
        # ToR switches
        tor1 = self.addSwitch('tor1', cls=Terminal, transceivers=[('32', 0*dBm)])
        ...

Servers are added using addHost() calls:

class TutorialTopo( Topo ):
        # Servers
        server1 = self.addHost('server1')
        ...

In Mininet, ports are created by specifying port numbers when we add links. (This is due to the underlying link emulation which uses Linux virtual Ethernet (veth) pairs.)

Because of this, we need to specify the correct port numbers when we create the links.

The base port numbers for a Lumentum ROADM20 are specified at the top of the file:

# Lumentum Roadm20 Port numbering
LINEIN, LINEOUT = 5101, 4201
ADD, DROP = 4100, 5200

The server and ToR port numbers are as specified above.

WDM fiber links are unidirectional and are added using wdmLink calls:

        # Inter-ROADM links
        # We put 22km of fiber between roadm2 and roadm3
        # Default fiber length is 1m if not specified
        ...
        self.wdmLink(roadm2, roadm3, LINEOUT, LINEIN, spans=[22*km])
        self.wdmLink(roadm3, roadm2, LINEOUT, LINEIN, spans=[22*km])
        ...
        # ROADM add/drop 2 <-> ToR transceiver links
        self.wdmLink(tor1, roadm4, 320, ADD+2)
        self.wdmLink(roadm4, tor1, DROP+2, 321)

We can see that LINEOUT of roadm2 is connected to LINEIN of roadm3 and vice-versa, with a 22km length of fiber in between, corresponding to a fiber spool in the COSMOS testbed. Later, add/drop port 2 of roadm4 is connected to ports 320/321 of tor1 (output/input, respectively).

Ethernet links are added sing addLink() calls:

        # Server<->ToR Ethernet links
        self.addLink(server1, tor1, port1=0, port2=1)
        self.addLink(server2, tor2, port1=0, port2=2)
        self.addLink(server3, tor3, port1=0, port2=3)

Creating the Mininet-Optical Network

All of these commands should be run in a terminal window for the VM or server where Mininet-Optical is installed.

We will run Mininet-Optical from the top directory of the source tree:

cd ~/mininet-optical

We should check to make sure that the tutorial scripts are present:

ls examples/cosmostutorial.py
ls examples/config-cosmostutorial.sh

If they are missing, we can fetch and install the appropriate branch:

git fetch
git checkout cosmos-tutorial
make install

Since the NETCONF agents for the ROADMs use SSL, we first have to generate a set of (self-signed) SSL certificates for them to use:

make certs

Now we should be able to run the tutorial script to create the emulated network:

sudo HOME=~ examples/cosmostutorial.py

This should start up Mininet-Optical, create the tutorial network, and start the CLI:

    COSM-IC mini-tutorial topology:

    roadm4 <-> roadm1 <-> roadm2 <-22km-> roadm3
     |          |                          |
    tor1       tor2                       tor3
     |          |                          |
    server1    server2                    server3

    This is for the COSMOS mini-tutorial at:
    https://wiki.cosmos-lab.org/wiki/Tutorials/Optical/MininetOpticalTutorial1
    
*** Starting CLI:
mininet-optical> 

Mininet-Optical CLI commands may be entered at the mininet-optical> prompt.

If you don't have one open already, open up another terminal window and connect to the Linux VM or server where Mininet-Optical is installed. You may wish to enter the source directory in this window as well:

cd ~/mininet-optical

Unless specified otherwise, all of the configuration commands below should be entered in this second window at the shell prompt.

ROADM Configuration

All of these configurations can be performed by Python scripts developed to work with the COSMOS test-bed. The Python commands send NETCONF commands to the ROADM.

Setting “Snake” Connection

(This is not currently part of the Mininet-Optical software emulated configuration.)

Transceiver 33 (ports 330/331) on ToR configuration

(This is not currently part of the Mininet-Optical software emulated configuration, but it would be: 60 (DWDM Channel C60) 1529,55 nm 196,00 Thz with frequency range [195.95,196.05] Thz)

MUX/DEMUX configuration

As a reminder, here are the ROADM port numbers:

  • ROADM 4:

DEMUX IN/OUT (ADD1/LINEOUT) port: 5101/5204 MUX IN/OUT (LINEIN/DROP1)port: 4104/4201

  • ROADM 1:

DEMUX IN/OUT (ADD1/LINEOUT) port: 5101/5201 MUX IN/OUT (LINEIN/DROP1) port: 4101/4201

  • ROADM 2:

DEMUX IN/OUT (ADD1/LINEOUT) port: 5101/5201 MUX IN/OUT (LINEIN/DROP1) port: 4101/4201

  • ROADM 3:

DEMUX IN/OUT (ADD1/LINEOUT) port: 5101/5204 MUX IN/OUT (LINEIN/DROP1) port: 4104/4201

Note that the servers are connected to ADD2/DROP2 while DROP1/ADD1 are used as passthrough ports between ROADM 1 and ROADM 2.

ALS Disable Sequence (for 60 seconds)

(This is not currently done in the Mininet-Optical configuration.)

Configuring ROADMs in Mininet-Optical

ROADMs in Mininet-Optical may be configured via several mechanisms. An internal Python API may be used for configuration within the script that creates the network. More realistically, two external SDN/RPC control interfaces are provided: a simple REST interface and a more realistic NETCONF interface which is partially compatible with the NETCONF interface of the hardware Lumentum ROADM20.

To start with, we will implement the connections using the REST API.

Setting “Experiment_1” Connections using REST

Configuring ToR1↔ToR2 Connection 1 on Mininet-Optical using REST

  • ROADM 4:
  1. Enable MUX port 4102 “From ToR 1”
  2. Add Connection “Exp1-FromTor1” with Input/ Output Port 4102/4201 with bandwidth [192.95;193.05]
  3. Enable DEMUX port 5202 “Towards ToR 1”
  4. Add Connection “Exp1-TorwardTor1” with I/O Port 5101/5202

192.95THz..193.05THz has a middle frequency of 193.00 THz, which corresponds to channel C32 on Mininet-Optical's default 50GHz channel grid. C1's middle frequency is 191350 GHz, so C34 is at 191350 + 33*50 = 193000 GHz.

We use curl to send a REST request to roadm4 to add/drop ch34:

    curl "localhost:8080/connect?node=roadm4&port1=4102&port2=4201&channels=34"
    curl "localhost:8080/connect?node=roadm4&port1=5101&port2=5202&channels=34"
  • ROADM 1:
  1. Enable MUX port 4102 “From ToR 2”
  2. Add Connection “From ToR 2” with I/O Port 4102/4201 with bandwidth [192.95;193.05]
  3. Enable DEMUX port 5202 “Towards ToR 2”
  4. Add Connection “Towards ToR 2” with I/O Port 5101/5202

We use curl to send a REST request to roadm1 to add/drop ch34:

    curl "localhost:8080/connect?node=roadm1&port1=4102&port2=4201&channels=34"
    curl "localhost:8080/connect?node=roadm1&port1=5101&port2=5202&channels=34"

Configuring ToR1↔ToR3 Connection 2 on Mininet-Optical using REST

  • ROADM 4 (Same As For Connection 1):
  1. Enable MUX port 4102 “From ToR 1”
  2. Add Connection “From ToR 1” with I/O Port 4102/4201 with bandwidth [192.95;193.05]
  3. Enable DEMUX port 5202 “Towards ToR 1”
  4. Add Connection “Towards ToR 1” with I/O Port 5101/5202 with bandwidth [192.95;193.05]
        curl "localhost:8080/connect?node=roadm4&port1=4102&port2=4201&channels=34"
        curl "localhost:8080/connect?node=roadm4&port1=5101&port2=5202&channels=34"
    
  • ROADM 1 <Not Same!>:
  1. Enable MUX port 4101 “Through Port” (enabled for Snake)
  2. Add Connection “Through In” with I/O Port 4101/4201 with bandwidth [192.95;193.05]
  3. Enable DEMUX port 5201 “Through Port” (enabled for Snake)
  4. Add Connection “Through Out” with I/O Port 5101/5201 with bandwidth [192.95;193.05]

This time we pass channel 34 through ROADM 1:

    curl "localhost:8080/connect?node=roadm1&port1=4101&port2=4201&channels=34"
    curl "localhost:8080/connect?node=roadm1&port1=5101&port2=5201&channels=34"
  • ROADM 2 (Same As For ROADM1):
  1. Enable MUX port 4101 “Through Port” (enabled for Snake)
  2. Add Connection “Through In” with I/O Port 4101/4201 with bandwidth [192.95;193.05]
  3. Enable DEMUX port 5201 “Through Port” (enabled for Snake)
  4. Add Connection “Through Out” with I/O Port 5101/5201 with bandwidth [192.95;193.05]

And pass through ROADM2:

    curl "localhost:8080/connect?node=roadm2&port1=4101&port2=4201&channels=34"
    curl "localhost:8080/connect?node=roadm2&port1=5101&port2=5201&channels=34"
  • ROADM 3 (Same As For ROADM4):
  1. Enable MUX port 4102 “From ToR 3”
  2. Add Connection “From ToR 3” with I/O Port 4102/4201 with bandwidth [192.95;193.05]
  3. Enable DEMUX port 5202 “Towards ToR 3”
  4. Add Connection “Towards ToR 3” with I/O Port 5101/5202 with bandwidth [192.95;193.05]

And we drop at ROADM3:

    curl "localhost:8080/connect?node=roadm3&port1=4102&port2=4201&channels=34"
    curl "localhost:8080/connect?node=roadm3&port1=5101&port2=5202&channels=34"

Setting “Experiment_1” Connections using NETCONF

(TBD)


Network Interfaces Configuration for Experiment_1

Setting Up ToR switches and configuring transceivers

Mininet-Optical's Terminal is the equivalent of the ToR switch which contains Ethernet interfaces as well as WDM transceivers.

Instead of using a Cisco-style CLI to configure it, we use its default REST API.

  1. Connecting Ethernet interfaces to Transceivers and set channel
curl "localhost:8080/connect?node=tor1&ethPort=1&wdmPort=320&wdmInPort=321&channel=34"
curl "localhost:8080/connect?node=tor2&ethPort=2&wdmPort=290&wdmInPort=291&channel=34"
curl "localhost:8080/connect?node=tor3&ethPort=3&wdmPort=310&wdmInPort=311&channel=34"
  1. Turn on all transceivers
curl "localhost:8080/turn_on?node=tor1"
curl "localhost:8080/turn_on?node=tor2"
curl "localhost:8080/turn_on?node=tor3"

Configuring Compute Nodes (server1, server2, server3)

  1. Configure Ethernet interfaces and assign IP addresses:

This may be performed in at the mininet-optical> CLI prompt:

mininet-optical> server1 ifconfig server1-eth0 192.168.1.1/24
mininet-optical> server2 ifconfig server2-eth0 192.168.1.2/24
minient-optical> server3 ifconfig server3-eth0 192.168.1.3/24

Or it can be done remotely from a shell prompt in the VM using the ~/mininet/util/m script:

~/mininet/util/m server1 ifconfig server1-eth0 192.168.1.1/24
~/mininet/util/m server2 ifconfig server2-eth0 192.168.1.2/24
~/mininet/util/m server3 ifconfig server3-eth0 192.168.1.3/24

Perform Experiment_1

  1. Establish Connection ToR1↔ToR2.
  2. Try ping from server1 to server3:
mininet-optical> server1 ping 192.168.1.3

  1. Establish Connection ToR1↔ToR3.
  2. Try ping from server1 to server3.

Shutting down Mininet-Optical

To exit Mininet-Optical, type exit or press control-D at the mininet-optical> prompt.

References

COSMOS Optical Tutorial 1: Tutorials/Optical/Tutorial1

Tutorial network script: https://github.com/Mininet-Optical/mininet-optical/blob/cosmos-tutorial/mnoptical/examples/cosmostutorial.py

Tutorial configuration script: https://github.com/Mininet-Optical/mininet-optical/blob/cosmos-tutorial/mnoptical/examples/config-cosmostutorial.sh

Mininet-Optical documentation: https://mininet-optical.org

Mininet-Optical code: https://github.com/mininet-optical/mininet-optical

(Packet) Mininet web site: https://mininet.org

Attachments (1)